ANSYS接觸分析錯誤,求解釋?
Contact element 9449 (real ID 3) status changes abruptly from contact
(with target element 8774) -> no-contact.
Contact element 9449 (real ID 3) status changes abruptly from contact
(with target element 8774) -> no-contact.
鄒正剛 
模型為四層結構,各層之間粘接連接起來,在頂層SiN薄膜中施加沿半徑方向的力,觀察各層薄膜滑移與相對彎曲情況。
建立模型為四分之一圓模型,通過接觸單元contact174連接,運用TB,,,BILI命令定義接觸區域材料屬性。由于上面三層薄膜厚度遠小于襯底厚度,為了簡化模型 定義頂層三層薄膜全部為一體 只有襯底和二氧化硅層之間會滑移。四分之一模型關于截面對稱。計算使整個四分之一模型的中軸線保持不動。接觸單元的選項和實常數設置為:
!*
KEYOPT,3,1,0
KEYOPT,3,2,0
KEYOPT,3,4,0
KEYOPT,3,5,2
KEYOPT,3,6,0
KEYOPT,3,7,1
KEYOPT,3,8,0
KEYOPT,3,9,0
KEYOPT,3,10,0
KEYOPT,3,11,0
KEYOPT,3,12,2
KEYOPT,3,14,0
KEYOPT,3,15,0
KEYOPT,3,16,0
!*
R,3,0,0,1, 0.01,0,0
RMORE,0,0,0, 0,0,0
RMORE,0,,, ,,
RMORE,,,0, 0,,
RMORE,,,,,,
RMORE,,,,,
計算的命令流設置如下:
TIME,0.1
AUTOTS,1
NSUBST,1000,1e6,10,1
KBC,0
!*
TSRES,ERASE
!*
NLGEOM,1
NROPT,FULL, ,OFF
STAOPT,DEFA
LUMPM,0
EQSLV, , ,0, ,DELE
MSAVE,0
PCGOPT,0, ,AUTO, , ,AUTO
PIVCHECK,1
PSTRESS,0
TOFFST,0,
!*
NEQIT,25,
!*
PRED,OFF
LNSRCH,1
SAVE
最后爆出來錯誤如下The L-2 norm of the residual force overflowed. This may be caused by PRED,ON or birth/dead elements. Please use PRED,OFF and try again。
求大神解釋
鄒正剛