共軛傳熱問題求教

瀏覽:6988 回答:6

1、使用fluent軟件進行共軛傳熱的模擬,網格劃分見附件。
2、其中固體部分為雙層套管,材質分別為碳鋼和鋁;
3、使用wb mesh完成網格劃分后,導入fluent后,在進行網格檢查時,出現錯誤提示,請問我應該如何處理。如下:
3.1、提示一:
Warning: zone of type interior found between different solids!
  Material of cell zone 5 is aluminum, while material of cell zone 6 is steel.
      This will adversely affect the solution.
      It is recommended that you fix this issue via the TUI command
      /mesh/modify-zones/slit-interior-between-diff-solids
3.2、提示二:
Setting Post Processing and Surfaces information ...Note: zone-surface: cannot create surface from sliding interface zone.
Creating empty surface.
Note: zone-surface: cannot create surface from sliding interface zone.
Creating empty surface.
Note: zone-surface: cannot create surface from sliding interface zone.
Creating empty surface.
Note: zone-surface: cannot create surface from sliding interface zone.
Creating empty surface.
         Done.共軛傳熱問題求教的圖1

結構圖.png


邀請回答 我來回答

全部回答

(2)
默認 最新
隨波逐流

從你圖片來看,你沒有共節點劃分網格,那么需要在fluent中定義interface的,否則交界面處不會有熱量傳遞;如果你劃分了共節點網格,那么在fluent中默認即可;可參考我的視頻

2019年1月3日
評論 4 點贊 1
阿莫西林_3870

你好,你的問題我也同樣遇到了,需要怎么解決,您有答案了嗎

2022年7月20日
評論 點贊