ABAQUS樁土接觸
瀏覽:3256 回答:4
樁側與土側采用摩擦約束,樁底和土底采用tie約束,計算地應力時,第一步就不收斂,警告信息里全是
If significant clearance/overclosure exists between surface pair (assembly__t45_anpo-1-2_sn,assembly__t45_anpo-1-2_m) and the master surface does not have rotational degrees of freedom, adjustment is recommended for correct enforcement of the tie constraint
Slave surface assembly__t46_anpo-1-2_sn is a node-based surface used with surface to surface approach. In order to obtain improved stress accuracy with this approach, an element-based surface should be used instead.
麻煩各位指點一下該如何解決,不勝感激

CAE從業者