注冊
/
登錄Surface based COHESIVE BEHAVIOR cannot be used for contact pair interactions. See the surface interaction named INTPROP-CO.

cohesive性質用general contact和surface to surface(explicit)都報錯,surface base cohesive contact只能用于bonded contact?
Once a pair of surfaces is used for *tie, it cannot be used again for *contact pair and vice versa.


abaqus 中當使用 硬接觸 功能中的 Allow separation after contact(不勾選)時,出現下列警告,請教下要怎么解決At least one non-blank surface must be specified for contact surface interactions referencing NO SEPARATION surface behavior

In all these cases, we recommend using single-sided surfaces under *CONTACT INITIALIZATION ASSIGNMENT to handle initial adjustments more precisely and avoid possible convergence problems.
Please remove the contact field output for the contact pair in question, or split the node-based surface into separate surfaces each spanning just one instance

for the out-of-plane thickness of the corresponding surface under *surface interaction.
At least one non-blank surface must be specified for contact surface interactions referencing NO SEPARATION surface behavior (see the surface interaction named INTPROP-1).這個問題怎么解決啊

跳至頁