登錄請問大家在進(jìn)行abaqus仿真時(shí),有沒有可能因?yàn)殡娔X睡眠或者斷網(wǎng)而造成這種錯(cuò)誤?
小弟做一個(gè)顆粒壓縮場景,材料就用彈塑性模型,顆粒模型核模具如圖,其中模具部分設(shè)置為了剛體,120s的顯式分析,加載為100MPa,現(xiàn)在有兩個(gè)問題,首先是計(jì)算過慢,如監(jiān)控器中所示,整體網(wǎng)格也就五萬多,CPU是9950x,14核計(jì)算,剛開始兩分鐘出0.06s,后面掉到0.004s了,模型也不大,質(zhì)量縮放給的5,該怎么優(yōu)化呢?此外就是算到2s多就出現(xiàn)標(biāo)題的提示報(bào)錯(cuò),上網(wǎng)查了說了網(wǎng)絡(luò)問題,但網(wǎng)絡(luò)一直連著,
有時(shí)候算了八九個(gè)小時(shí)了突然出現(xiàn)這個(gè)錯(cuò)誤,Process terminated by external request (SIGTERM or SIGINT received).請大神指點(diǎn)一下,有償咨詢
運(yùn)行一開始就出現(xiàn)Process terminated by external request (SIGTERM or SIGINT received).

.*** ABAQUS/standard rank 0 received the ABoRT signal*** ERROR CATEGORY: ELEMENT LOOP2023/8/9 17:17:49Abaqus Error: Abaqus/Standard Analysis exited with an error - Please see the

***ERROR: Process terminated by external request (SIGTERM or SIGINT received).試了從abaqus command運(yùn)行,還是這種錯(cuò)誤,cpu才占用百分之40啊。