Ls dyna求解時,出現以下問題沒法求解什么原因呢? 40

瀏覽:2491 回答:12

*** Warning 20339 (STR+339)

    nodal contact forces are available only

    for the master side with node to surface

    contact types of interface # 1


*** Warning 20535 (STR+535)

    contact interface # 1

    was switched from SOFT=2 to SOFT=1.

    The segment based contact option is only valid for

    contact types 3, a3, 4, 13, 14, 15, 10, and a10


*** Warning 20339 (STR+339)

    nodal contact forces are available only

    for the master side with node to surface

    contact types of interface # 2


*** Warning 20535 (STR+535)

    contact interface # 2

    was switched from SOFT=2 to SOFT=1.

    The segment based contact option is only valid for

    contact types 3, a3, 4, 13, 14, 15, 10, and a10


input of data is completed


initial kinetic energy = 0.00000000E+00


The LS-DYNA time step size should not exceed     2.235E-05

to avoid contact instabilities.  If the step size is

bigger then scale the penalty of the offending surface.

我是用的hypermesh導入ansys再輸出k文件求解的。然后就出現這些問題了。

邀請回答 我來回答

全部回答

(3)
默認 最新
每天進步一點點
你這問題多了,主要是接觸設置有誤。而且為什么還要導入ansys再導出k?
2019年1月18日
評論 3 點贊 2
藍牙

接觸設置的問題! 但是這個warning 不會導致計算不能進行

2019年1月20日
評論 5 點贊
青柏CAE

時間步搞小點不就完了嗎

2019年1月19日
評論 1 點贊