不知火舞的被虐|伊人天伊人天天综合网|博洛尼亚天气|任你懆这里只有精品4|久久美日韩精品久久|掌中之物漫画免费阅读观看|0丨d老妇

ansys中瞬態分析閃退問題? 20

瀏覽:2262 回答:2

ansys瞬態分析計算完成后顯示solution is done并且好好的,當進入后處理時就閃退了。

查看了error文件里面

 A reference force value times the tolerance is used by the              

 Newton-Raphson method for checking convergence.  The calculated         

 reference FORCE CONVERGENCE VALUE = 0 is less than a threshold.  This   

 threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL     

 command.  Check results carefully. 

yuanhui 13:12:25

 *** WARNING ***   SUPPRESSED MESSAGE    CP =      14.711   TIME= 12:00:40

 A reference force value times the tolerance is used by the              

 Newton-Raphson method for checking convergence.  The calculated         

 reference FORCE CONVERGENCE VALUE = 0 is less than a threshold.  This   

 threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL     

 command.  Check results carefully.                                      


 *** ERROR ***                           CP =    5956.570   TIME= 12:58:43

 An unexpected error ( SIG$SEGV ) has occurred...  ANSYS internal data   

 has been corrupted.  ANSYS is unable to recover and will terminate.     

 Previously saved files are unaffected.  Please send the data leading    

 to this operation to your technical support provider, as this will      

 allow ANSYS, Inc to improve the program.                                

只有最后一個error就是在進入/post26后出現的,其余都是warning。為什么計算收斂完成了還會出現這種情況呢?

邀請回答 我來回答

全部回答

(1)
默認 最新
鄒正剛

  這是一個內部錯。如果你是使用命令流進行計算的,當命令流中出現違反 ANSYS 規定的語句時,就有可能出現這種情況。

  使用 GUI 操作,計算結束后,進入 /post26,一般不會出現這種情況。

2018年10月19日
評論 1 點贊

沒解決?試試專家一對一服務

換一批
    App下載
    技術鄰APP
    工程師必備
    • 項目客服
    • 培訓客服
    • 平臺客服

    TOP