ansys中瞬態分析閃退問題? 20
ansys瞬態分析計算完成后顯示solution is done并且好好的,當進入后處理時就閃退了。
查看了error文件里面
A reference force value times the tolerance is used by the
Newton-Raphson method for checking convergence. The calculated
reference FORCE CONVERGENCE VALUE = 0 is less than a threshold. This
threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL
command. Check results carefully.
yuanhui 13:12:25
*** WARNING *** SUPPRESSED MESSAGE CP = 14.711 TIME= 12:00:40
A reference force value times the tolerance is used by the
Newton-Raphson method for checking convergence. The calculated
reference FORCE CONVERGENCE VALUE = 0 is less than a threshold. This
threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL
command. Check results carefully.
*** ERROR *** CP = 5956.570 TIME= 12:58:43
An unexpected error ( SIG$SEGV ) has occurred... ANSYS internal data
has been corrupted. ANSYS is unable to recover and will terminate.
Previously saved files are unaffected. Please send the data leading
to this operation to your technical support provider, as this will
allow ANSYS, Inc to improve the program.
只有最后一個error就是在進入/post26后出現的,其余都是warning。為什么計算收斂完成了還會出現這種情況呢?





















這是一個內部錯。如果你是使用命令流進行計算的,當命令流中出現違反 ANSYS 規定的語句時,就有可能出現這種情況。
使用 GUI 操作,計算結束后,進入 /post26,一般不會出現這種情況。