請問ANSYS在熱力耦合計算中出現如下問題改怎么解決? 100
最近在建立一個ANSYS熱力耦合模型,是先算溫度場,然后建立變形場之后用ldread,temp,last,,,,TEMP_1,rth命令導入溫度結果,但是在計算變形場出現下面問題:
The LS-DYNA time step size should not exceed 0.190E-06
to avoid contact instabilities. If the step size is
bigger then scale the penalty of the offending surface.
請問這個該怎么處理呢?
還有我溫度場用的solid45,變形場用的SOLID164單元可以嗎?
ET,1,SOLID164
mp,dens,1,4560
MPTEMP,1,0,100,200,300,400,1000
MPDATA,NUXY,1,,0.3,0.295,0.293,0.292,0.291,0.290
MPDATA,EX,1,,60.698e9,55e9,50e9,50e9,50e9,50e9
MPDATA,ALPX,1,,9.01E-006,9.01E-006,9.01E-006,9.01E-006,9.01E-006,9.01E-006
TB,BKIN,1,5,2,1
TBTEMp,0
TBDATA,,1.398E+009,2.27E+009,
TBTEMP,200
TBDATA,,6.29E+008,1.1E+009,
TBTEMP,500
TBDATA,,4.4E+007,0.187E+009,
TBTEMP,700
TBDATA,,0.3E+007,0.5E+007,
TBTEMP,1000
TBDATA,,0.5E+006,0.1E+007,
ET,2,SOLID164,0,,,,0 !砧板單元
edmp,rigid,2,6,7
MP,EX,2,2e10
MP,DENS,2,4560
MP,NUXY, 2,0.3
ET,3,SOLID164,0,,,,0 !砧板單元
edmp,rigid,3,7,7
MP,EX,3,2e10
MP,DENS,3,4560 !定義密度
MP,NUXY, 3,0.3
變形場中材料模型這么定義可以嗎?

鄒正剛