系列3-原創#cohesive+隱式分析+通用接觸 node numbering錯誤-徹底解決辦法!

1.jpg

在開始介紹解決方法之前,先回顧下這個問題的來源:

帖子1:(發現問題)

http://www.yqgqt.org.cn/content/post/420836

******

使用批量插入cohesive單元+通用接觸+standard隱式分析時出現了以前錯誤,導致inp文

件不能提交:

Abaqus6.14報錯信息為:

the node numbering might not be correct for element 10779 instance part-1-1

Abaqus2018報錯信息為:

Exhausted the contact constraint pool. Cutting back the time increment and redoing the current increment. Other wise, set the environment variable aba_gcont_pool_size to high or a numeric number (1,2,...) with 1 being equivalent to high.

 

帖子2:(尋找原因)

http://www.yqgqt.org.cn/content/post/421215

******

通過節點編號的查詢確定了abaqus報錯的單元的單元編號是沒有問題的,這時候我們注意到警告信息出現了節點調整的信息:

Not all the nodes that have been adjusted were printed. Specify *preprint,contact=yes for complete printout.

15416 nodes have been adjusted more than once. The subsequent adjustments may cause these nodes not to lie on their master surface. The nodes have been identified in node set WarnNodeAdjust.

那么我們檢查了.pre文件,發現確實對批量插入cohesive單元的模型進行分析時,如果使用通用接觸+隱式分析會出現節點調整問題

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

解決思路:

1 通過對.pre文件(我是在環境變量文件abaqus_v6.env中設置了split_dat=ON,如果你沒有設置,請到.dat文件中尋找)的仔細研究分析發現:

.

.

.

見收費內容

ABAQUS斷裂模擬收徒 ,保證快速學會各種ABAQUS斷裂模擬方法    1200/人(將享有各種插件以及程序,價值3000+、專門定制視頻、全程親自教學、各種模型調試及解答問題等等,傾囊相教)

以下內容為付費內容,請購買后觀看

   8人購買

附上總體分析流程、分析思路、解決辦法及相關文件