不知火舞的被虐|伊人天伊人天天综合网|博洛尼亚天气|任你懆这里只有精品4|久久美日韩精品久久|掌中之物漫画免费阅读观看|0丨d老妇

abaqus計算不收斂?

瀏覽:5062 回答:4

abaqus模型計算不收斂,錯誤為Too many attempts made for this increment

msg文件中error: 

MAX. PENETRATION ERROR 2.32051     AT NODE GP-1.795623 OF CONTACT PAIR
   (GENERAL_CONTACT_FACES_123,GENERAL_CONTACT_FACES_121)
   MAX. CONTACT FORCE ERROR -3.67923E+06 AT NODE GP-1.825535 OF CONTACT PAIR
   (GENERAL_CONTACT_FACES_064,GENERAL_CONTACT_FACES_061)
          PENETRATION ERROR TOO LARGE COMPARED TO DISPLACEMENT INCREMENT. AVERAGE FORCE                       40.6       TIME AVG. FORCE        40.6   
 LARGEST RESIDUAL FORCE            -9.092E+05   AT NODE          1   DOF  2
   INSTANCE:                                                                                
 LARGEST INCREMENT OF DISP.          3.83       AT NODE     819324   DOF  2
   INSTANCE: GP-1                                                                           
 LARGEST CORRECTION TO DISP.         3.83       AT NODE     819324   DOF  2
   INSTANCE: GP-1                                                                           
          FORCE     EQUILIBRIUM NOT ACHIEVED WITHIN TOLERANCE. AVERAGE MOMENT                      0.00       TIME AVG. MOMENT       306.   
                                                (FROM FORCE     FIELD)
 LARGEST RESIDUAL MOMENT            2.385E+07   AT NODE          1   DOF  6
   INSTANCE:                                                                                
 LARGEST INCREMENT OF ROTATION      1.241E-03   AT NODE          1   DOF  4
   INSTANCE: {assembly node}                                                                
 LARGEST CORRECTION TO ROTATION     1.241E-03   AT NODE          1   DOF  4
   INSTANCE: {assembly node}                                                                
          THE MOMENT    IS ZERO EVERYWHERE BUT THE MOMENT    RESIDUAL OR
          THE ROTATION CORRECTION IS NON-ZERO COMPATIBILITY ERRORS:
    TYPE                NUMBER EXCEEDING TOLERANCE  MAXIMUM ERROR        IN ELEMENT
 VOLUMETRIC                          0                2.256E-06            3715006
   INSTANCE: CYB-2                                                                          

邀請回答 我來回答

全部回答

(3)
默認 最新
微斯人_5532
現在解決了么?
2023年11月2日
評論 點贊
靜默的無線電
不收斂的原因很多的,得看具體模型
2019年10月22日
評論 1 點贊
billejun
到網上找下接觸不收斂的解決方案,研究下再調整自己的模型
2019年10月22日
評論 點贊

沒解決?試試專家一對一服務

換一批
    App下載
    技術鄰APP
    工程師必備
    • 項目客服
    • 培訓客服
    • 平臺客服

    TOP